500万彩票

Your location:Home > Products > Traffic Signal Controller > Traffic Signal Controller
Traffic Signal Controller

ZW2(36/16)-51-V-GLY

Views:772  Price:0  Order Online


Main Performance Index

1.       The master controller transmitter output:

- Lane: 3 phases lane control 9 ways

- Pedestrian: 2 ways pedestrian control 2 ways same direction output and 2ways reverse direction output.

The slave controller transmitter output:

- Lane: 3 phases lane control 9 ways

- Pedestrian: 2 ways pedestrian control 2 ways same direction output and 2 ways reverse direction output。

One set ZW2(36/16)-51-V-GLY traffic signal controller includes one master and three slaves.

2.       Each way load capacity3A, the master load capacity5A, the slave load capacity5A

3.       Working voltage: DC9V-36V

4.       Operating temperature: 20— 70

5.       Environment relative humidity: 20%--95% No condensation

6.       Environmental air pressure: 86—106 KPa

7.       Overall dimension:

Master: (length * width * height) 300mm*200mm*120mm

Slave: (length * width * height) 300mm*220mm*105mm

 


View Cart

 

Main Feature

1. The master and slaves are both have dual-band wireless module. It enhances the anti-jamming.

2. Power consumption: the master is less than 0.8W without load; the slave is less than 0.6W.

3。 Power reverse connection protection function。 The controller will not be damaged when the input power reverse connection。

4. Fault protecting function. The master and slaves will automatically become yellow flash when fault happened.

5。 The maximum output current of each way is 3A。

6. Control method: controlled by special PC software. It can control the current time and scheme of the signal controller.

7. It can be set to 18 kinds of control scheme.

8。 Traffic Signal Controller can be set to Weekday Scheme (Monday to Friday), Weekend Scheme (Saturday and Sunday), Special Day Scheme and Pedestrian Scheme。 The maximum special day scheme quantity is 20 and each scheme can be controlled separately。

9. Weekday Scheme: can be divided into 24 time interval. Each time interval can use one of the 18 control schemes together.

10. Weekend Scheme: can be divided into 24 time interval. Each time interval can use one of the 18 control schemes together.

11. Special Day Scheme: can be divided into 24 time interval. Each time interval can use one of the 18 control schemes together.

12。 The master and slaves are all have pedestrian crossing push button。 It can work according to the Pedestrian Scheme。

13. Traffic Signal Controller can be controlled by special remote-control unit.

14. About the usage of the remote-control unit

A Key is for controlling the vehicle traffic lights all Red, pedestrian traffic lights all Green

B Key on the remote-control unit is for stepping to next controlling state of the traffic signal controller.

C Key is for keeping the current state of the traffic signal controller within 120 seconds。 Push the C key again under this state, it will keep the current state within 120 seconds again。

D Key is for exit the remote-control controlling and the traffic light controller will enter into the automated state.

Please Note: Operation of Remote-control unit while it under using is allowed after 3 seconds of each new changed state. Traffic light receives new remote signal after lights state transition keeping 3 seconds according controller carrying out remote operation.

Main Performance Index

1.       The master controller transmitter output:

- Lane: 3 phases lane control 9 ways

- Pedestrian: 2 ways pedestrian control 2 ways same direction output and 2ways reverse direction output.

The slave controller transmitter output:

- Lane: 3 phases lane control 9 ways

- Pedestrian: 2 ways pedestrian control 2 ways same direction output and 2 ways reverse direction output.

One set ZW2(36/16)-51-V-GLY traffic signal controller includes one master and three slaves.

2.       Each way load capacity3A, the master load capacity5A, the slave load capacity5A

3.       Working voltage: DC9V-36V

4.       Operating temperature: 20— 70

5.       Environment relative humidity: 20%--95% No condensation

6.       Environmental air pressure: 86—106 KPa

7.       Overall dimension:

Master: (length * width * height) 300mm*200mm*120mm

Slave: (length * width * height) 300mm*220mm*105mm

 

广西快3计划 亿信彩票登陆 吉林快3 小米彩票是真的吗 天津11选5 北京两步彩走势图 小米彩票手机官网 亿信彩票手机app下载 山东11选5开奖 贵州快3